news

Why does the body of the quick-change system fall off after a power outage?

News

If the quick-change system’s plate falls off in the morning after a power outage at night, this typically indicates that the selected solenoid valve or related control valve in the quick-change system may not meet system requirements or is faulty, failing to maintain proper locking after the power is cut off.

1. The Role and Selection of Solenoid Valves

Solenoid valves are critical components in a quick-change system, used to control the opening and closing of air or liquid pathways to achieve locking and release. Choosing the correct solenoid valve is crucial for ensuring the system’s stability and reliability.

2. Possible Consequences of Choosing the Wrong Valve

Insufficient Locking Force:
If the selected solenoid valve has insufficient flow capacity or pressure, it may result in inadequate locking force. This could cause the quick-change system to fall off due to external factors (such as vibrations or impacts) after a power outage.

Poor Sealing:
If the solenoid valve has poor sealing performance, it may lead to gas or liquid leakage, compromising the locking effect. After a power outage, such leakage may worsen, causing the quick-change system to detach.

Unstable Control:
If the solenoid valve’s control is unstable, it may cause the quick-change system to experience jamming or malfunctions during locking and release. After a power outage, this instability may become more pronounced, leading to detachment.

3. How to Avoid Choosing the Wrong Valve

Define System Requirements:
Before selecting a solenoid valve, clearly define the quick-change system’s specific requirements and working conditions, including working pressure, flow rate, and type of medium.

Select the Right Solenoid Valve:
Choose a solenoid valve model and specifications that meet the system’s locking and release requirements.

Conduct Performance Testing:
Before installation, conduct performance tests on the solenoid valve to ensure proper functioning, good sealing, and stable control.

Perform Regular Maintenance and Inspections:
Regularly maintain and inspect the solenoid valve to detect and address potential issues promptly, ensuring long-term stable operation.

In conclusion, if the quick-change plate falls off in the morning after a power outage, it is important to check whether the solenoid valve selection is correct, whether there are faults, and whether it meets system requirements. By defining system requirements, selecting the right solenoid valve, conducting performance tests, and performing regular maintenance and inspections, you can effectively prevent detachment issues caused by choosing the wrong valve.

Need more information?
Contact us for more details about our products, solutions and services.
Online message

    Contact us
    Tel
    Tel
    +86 18836625868
    • Email:info@ltautotools.com
    • Add:No.11 Zhengtou Technology Innovation Park, Mazhai industrial zone, Erqi district
    • Zhengzhou, China, 450000
    Copyright © 2016 LH-TC Co.,Ltd 豫ICP备15030842号-1